Instructions for use of prostheses and service guide Amputees often wear prostheses . In order to ensure the normal use of prostheses, perform their functions well, and prolong their service life, the following items should be noted. 1. Formally accept the maintenance of the cavity: (including the sleeve silicone soft sleeve) 1. The upper limb arm tube and lower limb receiving cavity should be kept clean every day, cleaned before going to bed, and allowed to dry naturally. 2. After wearing the upper limb arm tube and lower limb receiving cavity for a period of time, the residual limb atrophy may sometimes occur. At this time, the residual limb socks can be worn or the leather pad can be adjusted to keep wearing and walking safe. If it is still too loose, please contact the company in time to avoid falling after slipping, and replace the receiving cavity if necessary. 3. Precautions for wearing silicone and gel soft covers: (Use correctly under the guidance of a technician) (1) Cleaning method: Clean the inner side with neutral soapy water every day, and air dry naturally. (It is better to use care solution). (2) Avoid scratches and tears from sharp and rough objects; avoid high temperature exposure and baking; avoid strong stretching. 2. Temporary receiving cavity and temporary prosthesis. 1. Temporary receiving cavity and temporary prosthesis are used for observation, shaping, and stabilization of residual limbs for amputees who are newly fitted with prostheses. 2. Temporary prostheses are only used for weight-bearing, support, joint mobility and training strength and sense of walking of the residual limb. 3. Maintenance of structural parts 1. The structural parts of the prosthesis can be used normally according to the after-sales warranty period. In general, we will go to the prosthesis company for maintenance and maintenance regularly for 3 to 6 months. If there is an abnormality, contact the prosthetic company to resolve it properly. 2. In order to prevent damage to the structure and prolong the service life of the prosthesis, the prosthesis should not be used and stored in humid or harsh environments. 3. The user is strictly prohibited to disassemble the prosthesis without the permission of the technician! 4. Vulnerable parts: Myoelectric hand skins, valve covers, belts, contour sponges, contour socks, etc. are not covered by the warranty, and should be used normally and reasonably, and pay attention to maintenance. Fourth, the phenomenon that is easy to appear when the prosthesis is first installed Blisters, discomfort, and muscle aches appear after the residual limb is put on the receiving cavity; back muscles are sore and painful; the healthy leg may be prone to fatigue or pain due to too much weight. 5. Daily care of residual limbs 1. Keep the residual limbs clean every day and check the changes of the residual limbs at any time. 2. Check the skin of the residual limb in contact with the receiving cavity or arm tube every day. If there is any abnormality, seek medical treatment or contact the prosthetic company. So that it can be resolved in time. During the treatment, you are reminded that it is best not to wear prosthetics or wear less prostheses until healed, so as to avoid aggravating infections and other unexpected occurrences. Sixth, some suggestions 1. Pay attention to the height of the heel when wearing prostheses and changing shoes. Newcomers should not wear flat shoes, and wear travel shoes and casual shoes as much as possible. When changing shoes, the heel height should not exceed plus or minus 7.5px-12.5px when the prosthesis was first installed. Or contact a prosthetic company. 2. In order to make the prosthesis comfortable to wear, each wearer should pay attention to keeping the weight plus or minus no more than 3 kg. 3. Patients with pathological amputation or special skin (such as skin grafts, adhesive skin, etc.) should follow the instructions of the technician when wearing prostheses. 4. Pay attention to the changes of the skin during the change of seasons. Skin wrinkles and dryness are prone to occur, and care should be taken to moisturize and protect the skin. 7. Precautions for myoelectric hand skin, precautions for the use of batteries and how to use the charger 1. Be careful not to touch sharp objects and ink on the hand skin of myoelectric hand to avoid damage and dirt (all dirt can't be washed off). 2. The battery must be charged with a dedicated battery charger. Keep away from heat sources during storage and keep in a low temperature, dry environment. 3. Don't throw the battery into fire or water. Do not disassemble or modify the packaged battery by yourself. 4. For long-term storage, 50% discharge state must be maintained. 5. Connect the DC output circular plug of the charger to the socket of the charging base, and insert the power plug of the charger into an AC 220v power socket. At this time, the yellow indicator light in the middle of th

Instructions for use of prostheses and service guide

Amputees often wear prostheses . In order to ensure the normal use of prostheses, perform their functions well, and prolong their service life, the following items should be noted.

1. Formally accept the maintenance of the cavity: (including the sleeve silicone soft sleeve)

1. The upper limb arm tube and lower limb receiving cavity should be kept clean every day, cleaned before going to bed, and allowed to dry naturally.

2. After wearing the upper limb arm tube and lower limb receiving cavity for a period of time, the residual limb atrophy may sometimes occur. At this time, the residual limb socks can be worn or the leather pad can be adjusted to keep wearing and walking safe. If it is still too loose, please contact the company in time to avoid falling after slipping, and replace the receiving cavity if necessary.

3. Precautions for wearing silicone and gel soft covers: (Use correctly under the guidance of a technician)

(1) Cleaning method: Clean the inner side with neutral soapy water every day, and air dry naturally. (It is better to use care solution).

(2) Avoid scratches and tears from sharp and rough objects; avoid high temperature exposure and baking; avoid strong stretching.

2. Temporary receiving cavity and temporary prosthesis.

1. Temporary receiving cavity and temporary prosthesis are used for observation, shaping, and stabilization of residual limbs for amputees who are newly fitted with prostheses.

2. Temporary prostheses are only used for weight-bearing, support, joint mobility and training strength and sense of walking of the residual limb.

3. Maintenance of structural parts

1. The structural parts of the prosthesis can be used normally according to the after-sales warranty period. In general, we will go to the prosthesis company for maintenance and maintenance regularly for 3 to 6 months. If there is an abnormality, contact the prosthetic company to resolve it properly.

2. In order to prevent damage to the structure and prolong the service life of the prosthesis, the prosthesis should not be used and stored in humid or harsh environments.

3. The user is strictly prohibited to disassemble the prosthesis without the permission of the technician!

4. Vulnerable parts: Myoelectric hand skins, valve covers, belts, contour sponges, contour socks, etc. are not covered by the warranty, and should be used normally and reasonably, and pay attention to maintenance.

Fourth, the phenomenon that is easy to appear when the prosthesis is first installed

Blisters, discomfort, and muscle aches appear after the residual limb is put on the receiving cavity; back muscles are sore and painful; the healthy leg may be prone to fatigue or pain due to too much weight.

5. Daily care of residual limbs

1. Keep the residual limbs clean every day and check the changes of the residual limbs at any time.

2. Check the skin of the residual limb in contact with the receiving cavity or arm tube every day. If there is any abnormality, seek medical treatment or contact the prosthetic company. So that it can be resolved in time.

During the treatment, you are reminded that it is best not to wear prosthetics or wear less prostheses until healed, so as to avoid aggravating infections and other unexpected occurrences.

Sixth, some suggestions

1. Pay attention to the height of the heel when wearing prostheses and changing shoes. Newcomers should not wear flat shoes, and wear travel shoes and casual shoes as much as possible. When changing shoes, the heel height should not exceed plus or minus 7.5px-12.5px when the prosthesis was first installed. Or contact a prosthetic company.

2. In order to make the prosthesis comfortable to wear, each wearer should pay attention to keeping the weight plus or minus no more than 3 kg.

3. Patients with pathological amputation or special skin (such as skin grafts, adhesive skin, etc.) should follow the instructions of the technician when wearing prostheses.

4. Pay attention to the changes of the skin during the change of seasons. Skin wrinkles and dryness are prone to occur, and care should be taken to moisturize and protect the skin.

7. Precautions for myoelectric hand skin, precautions for the use of batteries and how to use the charger

1. Be careful not to touch sharp objects and ink on the hand skin of myoelectric hand to avoid damage and dirt (all dirt can't be washed off).

2. The battery must be charged with a dedicated battery charger. Keep away from heat sources during storage and keep in a low temperature, dry environment.

3. Don't throw the battery into fire or water. Do not disassemble or modify the packaged battery by yourself.

4. For long-term storage, 50% discharge state must be maintained.

5. Connect the DC output circular plug of the charger to the socket of the charging base, and insert the power plug of the charger into an AC 220v power socket. At this time, the yellow indicator light in the middle of the charging base is on to indicate that the power is connected.

6. Turn on the switch on the battery box, turn the switch to the "on" position, insert the battery box into the battery slot of the charging base, the red indicator light on the side of the battery slot lights up to indicate the charging status, when the red indicator light is off, the green indicator light is on When it starts, it means that the charging is complete .

 

SHIJIAZHUANG AOSUO O&P

Keywords:

You Can Also Learn More About Industry Trends

Oct 05,2026

Mechanical vs. Hydraulic vs. Pneumatic Knee Joints: Which Type Suits Your Target Market

Choosing between mechanical, hydraulic, and pneumatic knee joints affects walking safety, comfort, maintenance, and the final cost of a transfemoral prosthesis. This comparison of mechanical vs. hydraulic vs. pneumatic knee joints is designed for people seeking the best prosthetic knee joint supplier or a prosthetic knee joint for active users. A mechanical knee may suit a predictable daily.

Aug 31,2026

LinkWell Rehabilitation Equipment Co., Ltd. to Exhibit at 2026 China International Welfare Expo in Beijing

LinkWell Rehabilitation Equipment Co., Ltd. is pleased to announce its participation in the 2026 China International Welfare Expo & China International Rehabilitation Expo, taking place from September 3 to 5, 2026, at the China National Convention Center in Beijing. Visitors are warmly invited to visit Booth 1E20 to discover our prosthetic components, rehabilitation products, and customized solutions.

Jul 31,2026

AUSUO Launchs High-Performance Heat Resistant Safety Gloves for Industrial Protection

AUSUO proudly introduces its premium Heat Resistant Safety Gloves, engineered for superior thermal protection in demanding industrial environments. Designed for foundries, metal forging, welding, glass manufacturing, and high-temperature operations, these gloves combine excellent heat resistance, heavy-duty durability, and all-day comfort. Backed by professional manufacturing, CE & ISO certifications, and flexible OEM & ODM services, AUSUO provides reliable hand protection solutions for global distributors and industrial buyers.

Jul 30,2026

Aosuo Launches Custom Prosthetic Knee Joint with Professional OEM & ODM Manufacturing Services

Aosuo Medical proudly announces its Custom Prosthetic Knee Joint, offering complete OEM and ODM manufacturing solutions for distributors, prosthetic brands, rehabilitation centers, and medical suppliers worldwide. With over 10 years of production experience, CE and ISO certifications, and advanced manufacturing capabilities, Aosuo provides reliable, high-quality prosthetic components tailored to customers' specific requirements.