Analysis of the reasons for the failure of wearing a prosthesis


Release Time:

Jan 24,2022

Analysis of the reasons for the failure of wearing a prosthesis   1. Amputation       Amputation refers to amputation and amputation. Amputation is a painful thing in people's eyes. But from a rehabilitation perspective, amputation is not only a destructive procedure, but the beginning of functional reconstruction. Prosthetics can replace part of the amputation function through amputation, mutilated limbs and reorganization of prostheses to take care of themselves and return to society.       2. General requirements for the fitting of residual limb prostheses       1. The residual limb should have an appropriate length to ensure sufficient leverage, but there should be some space for the joint part of the prosthesis.       2. Residual joints should maintain the original physiological function as much as possible, and no contracture deformity should occur.       3. The stump should be covered with soft tissue, and there should be no tenderness, bone spurs and neuromas.       4. The residual limb should have good skin parts, healthy and smooth, less scar adhesion, and no sinus ulcer.   In the above aspects, except that the length of the residual limb depends on the amputation site, the other three aspects are related to factors such as surgical technique, postoperative care, treatment, and training. In order to ensure a good residual limb condition, so that the amputation can be well integrated with the prosthetic function, the medical profession and the prosthetic circle need to be closely integrated.   SHIJIAZHUANG AOSO O&P

Analysis of the reasons for the failure of wearing a prosthesis

 

1. Amputation

 

    Amputation refers to amputation and amputation. Amputation is a painful thing in people's eyes. But from a rehabilitation perspective, amputation is not only a destructive procedure, but the beginning of functional reconstruction. Prosthetics can replace part of the amputation function through amputation, mutilated limbs and reorganization of prostheses to take care of themselves and return to society.

 

    2. General requirements for the fitting of residual limb prostheses

 

    1. The residual limb should have an appropriate length to ensure sufficient leverage, but there should be some space for the joint part of the prosthesis.

 

    2. Residual joints should maintain the original physiological function as much as possible, and no contracture deformity should occur.

 

    3. The stump should be covered with soft tissue, and there should be no tenderness, bone spurs and neuromas.

 

    4. The residual limb should have good skin parts, healthy and smooth, less scar adhesion, and no sinus ulcer.

 

In the above aspects, except that the length of the residual limb depends on the amputation site, the other three aspects are related to factors such as surgical technique, postoperative care, treatment, and training. In order to ensure a good residual limb condition, so that the amputation can be well integrated with the prosthetic function, the medical profession and the prosthetic circle need to be closely integrated.

 

SHIJIAZHUANG AOSO O&P

Keywords:

You Can Also Learn More About Industry Trends

Oct 05,2026

Mechanical vs. Hydraulic vs. Pneumatic Knee Joints: Which Type Suits Your Target Market

Choosing between mechanical, hydraulic, and pneumatic knee joints affects walking safety, comfort, maintenance, and the final cost of a transfemoral prosthesis. This comparison of mechanical vs. hydraulic vs. pneumatic knee joints is designed for people seeking the best prosthetic knee joint supplier or a prosthetic knee joint for active users. A mechanical knee may suit a predictable daily.

Aug 31,2026

LinkWell Rehabilitation Equipment Co., Ltd. to Exhibit at 2026 China International Welfare Expo in Beijing

LinkWell Rehabilitation Equipment Co., Ltd. is pleased to announce its participation in the 2026 China International Welfare Expo & China International Rehabilitation Expo, taking place from September 3 to 5, 2026, at the China National Convention Center in Beijing. Visitors are warmly invited to visit Booth 1E20 to discover our prosthetic components, rehabilitation products, and customized solutions.

Jul 31,2026

AUSUO Launchs High-Performance Heat Resistant Safety Gloves for Industrial Protection

AUSUO proudly introduces its premium Heat Resistant Safety Gloves, engineered for superior thermal protection in demanding industrial environments. Designed for foundries, metal forging, welding, glass manufacturing, and high-temperature operations, these gloves combine excellent heat resistance, heavy-duty durability, and all-day comfort. Backed by professional manufacturing, CE & ISO certifications, and flexible OEM & ODM services, AUSUO provides reliable hand protection solutions for global distributors and industrial buyers.

Jul 30,2026

Aosuo Launches Custom Prosthetic Knee Joint with Professional OEM & ODM Manufacturing Services

Aosuo Medical proudly announces its Custom Prosthetic Knee Joint, offering complete OEM and ODM manufacturing solutions for distributors, prosthetic brands, rehabilitation centers, and medical suppliers worldwide. With over 10 years of production experience, CE and ISO certifications, and advanced manufacturing capabilities, Aosuo provides reliable, high-quality prosthetic components tailored to customers' specific requirements.